PRODUCTS

Varistor

NTC Thermistor

Film Capacitor

Ceramic Capacitor

Temperature Sensor

5D K Series

DIMENSION

Unit:mm

Series Varistor Voltage Tmax
5D 18V ~ 39V 3.8
47V ~ 68V 4.3
82V ~ 150V 3.8
180V ~ 270V 4.2
330V ~ 390V 4.8
430V ~ 560V 5.6
620V ~ 750V 6.4

Note: If the foot shape is non-linear, such as curved outward, it is usually Hmax=12mm

ELECTRICAL CHARACTERISTICS

Part No. Tick if Cutting Lead is needed Lead Lengh
(Unit:mm
up to one decimal place)
Upper Category Temperature Download
HEL 5D180K Download
HEL 5D220K Download
HEL 5D270k Download
HEL 5D330K Download
HEL 5D390K Download
HEL 5D470K Download
HEL 5D560K Download
HEL 5D680K Download
HEL 5D820K Download
HEL 5D101K Download
HEL 5D121K Download
HEL 5D151K Download
HEL 5D181K Download
HEL 5D201K Download
HEL 5D221K Download
HEL 5D241K Download
HEL 5D271K Download
HEL 5D301K Download
HEL 5D331K Download
HEL 5D361K Download
HEL 5D391K Download
HEL 5D431K Download
HEL 5D471K Download
HEL 5D511K Download
HEL 5D561K Download
HEL 5D621K Download
HEL 5D681K Download
HEL 5D751K Download

·180至680最大限制电压测试电流是1A.

Classification according to 8/20μs Surge current

Product Level K
Coventional Version
KJ
Enhanced Version
KH
Super Enhanced Version
KX
Custom made Version
Part No. V1mA(V) Withstanding
Surge
Current
(Imax)
(A)
Impulse
Current
15 times
8/20μs
(A)
Withstanding
Surge
Current
(Imax)
(A)

Impulse
Current
15 times
8/20μs
(A)
Withstanding
Surge
Current
(Imax)
(A)
Impulse
Voltage
40 times
(1.2/50μs)
(V)
Super High Energy
5D 82~750 400 150 800 250 800 1000 Example 
14D instead of 20D

Example
HEL14D561KX reach
6KV/3KA 100 times 
7D 82~820 1200 500 1750 1000 1750 2000
10D 82~1800 2500 1500 3500 1500 3500 4000
14D 82~1800 4500 3000 6000 3000 6000 6000
20D 82~1800 6500 3000 10000 5000 10000 10000
5D 18~68 100 250 150
7D 18~68 250 500 250
10D 18~68 500 1000 500
14D 18~68 1000 2000 1000
20D 18~68 2000 3000 1000
In accordance with
International and
National Standards
IEC61051-1          GB/T10193
IEC61051-2          GB/T10194
IEC61051-2-2       GB/T10195
CSA-C22.2
UL1449  
Include the
left column, and add the following:   
IEC60950-1:2005/Annex Q   
GB4943.1-2011   GB8898-2011   
UL1449  
Include the
left column, and add the following:   
IEC61000-4-5   GB/T17626.5   
IEC61643-331   GB/T18802.331   

Remark: the Impluse voltage testing standards(1.2/50μs) with 40 times are only applicable to the products which with the varistor voltage more than 430V.

Safety regulation certification and Corresponding models

Part No. 5D 7D 10D 14D 20D
180
220
270
330
390
470
560
680
820
101
121
151
181
201
221
241
271
301
331
361
391
431
471
511
561
621
681
751 ——
781
821
911 —— ——
951
102
112
152 —— ——
182 —— ——
Remark:
CQC(GB/T10193,GB/T10194).
UL1449(VZCA2/UL,VZCA8/C-UL), 105℃,125℃,130℃.
VDE(IEC61051-1,-2,-2-2).
CSA(C22.2 No.269.5-17).
Q1 = CQC(GB4943.1,GB8898).
Q2 = VDE(IEC60950-1 Annex.Q).
The aforementioned certification specifications may be subject to change. If necessary, please promptly request the latest version from the Quality Control Department.

Derating curves & V/I characteristics

Derating Curves

The horizontal axis is the impulse time that is the width of the surge waveform, the vertical axis is the peak value of the impulse current, and the number on the line is the number of impulses.

Maximum surge current imax = f(tr,pulse train)

v/i characteristics

A=Leakage current,

B = Protection level for worst-case varistor tolerances