Unit:mm
| Series | Varistor Voltage | Tmax |
|---|---|---|
| 20D | 18V ~ 39V | 5.1 |
| 47V ~ 68V | 5.6 | |
| 82V ~ 150V | 5.1 | |
| 180V ~ 270V | 5.7 | |
| 330V ~ 390V | 6.1 | |
| 430V ~ 560V | 6.7 | |
| 620V ~ 780V | 7.7 | |
| 820V ~ 1200V | 8.9 | |
| 1300V ~ 1500V | 10 | |
| 1600V ~ 1800V | 11.8 |
Note: If the foot shape is non-linear, such as curved outward, it is usually Hmax=27mm
| Part No. | Varistor Voltage | Maximum Allowable Voltage | Maximum Clamping Voltage | Withstanding Surge Current | Electrode Type | Packing Method | Lead Form | Tick if Cutting Lead is needed | Lead Lengh (Unit:mm up to one decimal place) |
Upper Category Temperature | Download | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| V1mA (V) |
AC (V) |
DC (V) |
V100A (V) |
Imax (8/20μs) (A) |
In(15次) (8/20μs) (A) |
||||||||
| HEL 20D180K | 18(16~20) | 11 | 14 | ·38 | 2000 | — | Download | ||||||
| HEL 20D220K | 22(20~24) | 14 | 18 | ·43 | 2000 | — | Download | ||||||
| HEL 20D270K | 27(24~30) | 17 | 22 | ·53 | 2000 | — | Download | ||||||
| HEL 20D330K | 33(30~36) | 20 | 26 | ·65 | 2000 | — | Download | ||||||
| HEL 20D390K | 39(35~43) | 25 | 31 | ·77 | 2000 | — | Download | ||||||
| HEL 20D470K | 47(42~52) | 30 | 38 | ·93 | 2000 | — | Download | ||||||
| HEL 20D560K | 56(50~62) | 35 | 45 | ·110 | 2000 | — | Download | ||||||
| HEL 20D680K | 68(61~75) | 40 | 56 | ·135 | 2000 | — | Download | ||||||
| HEL 20D820K | 82(74~90) | 50 | 65 | 135 | 6500 | 3,000 | Download | ||||||
| HEL 20D101K | 100(90~110) | 60 | 85 | 165 | 6500 | 3,000 | Download | ||||||
| HEL 20D121K | 120(108~132) | 75 | 100 | 200 | 6500 | 3,000 | Download | ||||||
| HEL 20D151K | 150(135~165) | 95 | 125 | 250 | 6500 | 3,000 | Download | ||||||
| HEL 20D181K | 180(162~198) | 115 | 150 | 300 | 6500 | 3,000 | Download | ||||||
| HEL 20D201K | 200(185~225) | 130 | 170 | 340 | 6500 | 3,000 | Download | ||||||
| HEL 20D221K | 220(198~242) | 140 | 180 | 360 | 6500 | 3,000 | Download | ||||||
| HEL 20D241K | 240(216~264) | 150 | 200 | 395 | 6500 | 3,000 | Download | ||||||
| HEL 20D271K | 270(243~297) | 175 | 225 | 455 | 6500 | 3,000 | Download | ||||||
| HEL 20D301K | 300(270~330) | 195 | 250 | 505 | 6500 | 3,000 | Download | ||||||
| HEL 20D331K | 330(297~363) | 210 | 275 | 550 | 6500 | 3,000 | Download | ||||||
| HEL 20D361K | 360(324~396) | 230 | 300 | 595 | 6500 | 3,000 | Download | ||||||
| HEL 20D391K | 390(351~429) | 250 | 320 | 650 | 6500 | 3,000 | Download | ||||||
| HEL 20D431K | 430(387~473) | 275 | 350 | 710 | 6500 | 3,000 | Download | ||||||
| HEL 20D471K | 470(423~517) | 300 | 385 | 775 | 6500 | 3,000 | Download | ||||||
| HEL 20D511K | 510(459~561) | 320 | 418 | 842 | 6500 | 3,000 | Download | ||||||
| HEL 20D561K | 560(504~616) | 350 | 460 | 920 | 6500 | 3,000 | Download | ||||||
| HEL 20D621K | 620(558~682) | 385 | 505 | 1,025 | 6500 | 3,000 | Download | ||||||
| HEL 20D681K | 680(612~748) | 420 | 560 | 1,120 | 6500 | 3,000 | Download | ||||||
| HEL 20D751K | 750(675~825) | 460 | 615 | 1,240 | 6500 | 3,000 | Download | ||||||
| HEL 20D781K | 780(702~858) | 485 | 640 | 1,290 | 6500 | 3,000 | Download | ||||||
| HEL 20D821K | 820(738~902) | 510 | 670 | 1,355 | 6500 | 3,000 | Download | ||||||
| HEL 20D911K | 910(819~1001) | 550 | 745 | 1,500 | 6500 | 3,000 | Download | ||||||
| HEL 20D951K | 950(855~1045) | 580 | 780 | 1,570 | 6500 | 3,000 | Download | ||||||
| HEL 20D102K | 1000(900~1100) | 625 | 825 | 1,650 | 6500 | 3,000 | Download | ||||||
| HEL 20D112K | 1100(990~1210) | 680 | 895 | 1,815 | 6500 | 3,000 | Download | ||||||
| HEL 20D152K | 1500(1350~1650) | 900 | 1220 | 2,475 | 6500 | 3,000 | Download | ||||||
| HEL 20D182K | 1800(1620~1980) | 1000 | 1465 | 2,970 | 6500 | 3,000 | Download |
·180至680最大限制电压测试电流是25A.
| Product Level | K Coventional Version |
KJ Enhanced Version |
KH Super Enhanced Version |
KX Custom made Version |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Part No. | V1mA(V) |
Withstanding Surge Current (Imax) (A) |
Impulse
Current 15 times 8/20μs (A) |
Withstanding Surge Current (Imax) (A) |
Impulse Current 15 times 8/20μs (A) |
Withstanding Surge Current (Imax) (A) |
Impulse
Voltage 40 times (1.2/50μs) (V) |
Super High Energy | ||||
| 5D | 82~750 | 400 | 150 | 800 | 250 | 800 | 1000 | Example
14D instead of 20D Example HEL14D561KX reach 6KV/3KA 100 times |
||||
| 7D | 82~820 | 1200 | 500 | 1750 | 1000 | 1750 | 2000 | |||||
| 10D | 82~1800 | 2500 | 1500 | 3500 | 1500 | 3500 | 4000 | |||||
| 14D | 82~1800 | 4500 | 3000 | 6000 | 3000 | 6000 | 6000 | |||||
| 20D | 82~1800 | 6500 | 3000 | 10000 | 5000 | 10000 | 10000 | |||||
| 5D | 18~68 | 100 | — | 250 | 150 | — | — | |||||
| 7D | 18~68 | 250 | — | 500 | 250 | — | — | |||||
| 10D | 18~68 | 500 | — | 1000 | 500 | — | — | |||||
| 14D | 18~68 | 1000 | — | 2000 | 1000 | — | — | |||||
| 20D | 18~68 | 2000 | — | 3000 | 1000 | — | — | |||||
|
In accordance with International and National Standards |
IEC61051-1 GB/T10193 IEC61051-2 GB/T10194 IEC61051-2-2 GB/T10195 CSA-C22.2 UL1449 |
Include the left column, and add the following: IEC60950-1:2005/Annex Q GB4943.1-2011 GB8898-2011 UL1449 |
Include the left column, and add the following: IEC61000-4-5 GB/T17626.5 IEC61643-331 GB/T18802.331 |
|||||||||
Remark: the Impluse voltage testing standards(1.2/50μs) with 40 times are only applicable to the products which with the varistor voltage more than 430V.
| Part No. | 5D | 7D | 10D | 14D | 20D |
|---|---|---|---|---|---|
| 180 |
![]() |
![]() |
![]() |
![]() |
![]() |
| 220 | |||||
| 270 | |||||
| 330 | |||||
| 390 | |||||
| 470 | |||||
| 560 | |||||
| 680 | |||||
| 820 |
![]() |
![]() |
![]() |
![]() |
![]() |
| 101 | |||||
| 121 | |||||
| 151 | |||||
| 181 | |||||
| 201 |
![]() |
![]() |
![]() |
![]() |
![]() |
| 221 | |||||
| 241 | |||||
| 271 | |||||
| 301 | |||||
| 331 | |||||
| 361 | |||||
| 391 | |||||
| 431 |
![]() |
![]() |
![]() |
![]() |
![]() |
| 471 | |||||
| 511 |
![]() |
||||
| 561 | |||||
| 621 |
![]() |
||||
| 681 |
![]() |
![]() |
|||
| 751 | —— | ||||
| 781 | |||||
| 821 | |||||
| 911 | —— | —— | |||
| 951 | |||||
| 102 | |||||
| 112 | |||||
| 152 | —— | —— |
![]() |
![]() |
![]() |
| 182 | —— | —— |
![]() |
![]() |
![]() |
The horizontal axis is the impulse time that is the width of the surge waveform, the vertical axis is the peak value of the impulse current, and the number on the line is the number of impulses.
Maximum surge current imax = f(tr,pulse train)
A=Leakage current,
B = Protection level for worst-case varistor tolerances